1、Bief introduction


    Fan pipe unit suit for concentrated controuing system.available for different using demand with variable load performance low noisy running can futher satisfy controtting noisy demand.compelet strains,superior performance, widely used in apartment,mansion hotel.
     The fan coil produced by our comany has seven kinds:horizontal cassette,vertical cassetle.vertical open load, block type, hanging type,pillar type.The air flow is between from 350mm3per hour to 2000 per hour cooling volume is between 2000 to 10600w and can increase unit surplus pressure according to special demand(fitt high static voltage fan code P)。


high efficience:copper casing aluminum plate,itaty ams assembly line.
small volume:unit shell thickness only 230mm,tight dimenshon, covinient pipe wiring, position installation easily.
chilled storepile water place use only once moulded in shaped, in and out spray enamel paint, only once heating insulation layer,no mold seepage.insulation layer can't be easily crashed.
There are left and right (facing the air supply outlet, intake direction)
Customer's can choose the part our company supplied, such as below: three grade regulation switch auto controlling system, all kinds of alum num air supply outlet and scatler current apparatus.

2、Type & Specification


3、installation usage and maintainance

when installing unit,should keep horizontal or make the pipe just a little lower the other side, so that insure remove chilled water,inlet/out let pipe should instal valve, so regulate water volume, in order to check and repair, water supply pipe and branch pipe should be connected with plastic node which can reduce pipe's shake noisy.

all the woring should adhere to the demand of electronics wiring diagram and wiring colour singal, or the motor will be burn.
When using should first open running fan of heating converter.if no mechanic meet that can connect power, and take notice to the direction of fan.
When using should first open the air supply valve, remove the air in the pip, Can see the water out that close the valve.
Heating converter should timely remove, keep well air fluid, that insure the best heat state, filter should timely wash, make the recirculation air smoothly.

4、order instruction

1、Clear the model and specification of product.and indicate the outlet or inlet direction.

2、Choose high static pressure, please indicate the model that is in the end add "P".

3、The customer with special demand, during signed the contract, should supply technology appid.

4、All the product need fit three speed suitch or auto controouing system, should additional order goods.